CAP |
N/A 1000 pF |
VMAX (DC) |
N/A 14 kV |
fL |
N/A 2.43 MHz |
SMAX |
N/A 1500 kV·A |
fH |
N/A 2.38 MHz |
IMAX (RMS) |
N/A 150 A |
Operating Temperature Range |
N/A -55 to +85 ºC |
Storage Temperature Range |
N/A -55 to 125 ºC |
Capacitance Tolerance |
N/A ±20% (Standard) ±10% (Optional) |
Maximum Dissipation Factor |
N/A 0.05% |
Dielectric Strength |
N/A Will withstand an AC potential of 1.4 times Rated Working Voltage for 10 Seconds at 25ºC. |
Minimum Insulation Resistance |
N/A 10000 MΩ |
Standard Markings |
N/A "HEC", Capacitance, Tolerance, Rated Working Voltage (VDC), Maximum Frequency, Maximum Reactive Power, Maximum Current and Date Code |
Maximum Capacitor Temperature |
N/A The maximum allowable temperature of the Inner Terminal is 100ºC. |
Maximum Temperature Rise |
N/A The maximum allowable temperature rise is 10ºC with an inlet temperature of 25ºC. |
Inlet Water Temperature |
N/A 30ºC or less recommended; not to exceed 50ºC when capacitor cooling is chained |
Cooling Water Pressure |
N/A Not to exceed 60 PSIA (132 feet of H2O) |
Closed System Derating |
N/A Increase Cooling Flow by 20% when antifreeze is used |